Skip Navigation
Skip to contents

Cancer Res Treat : Cancer Research and Treatment

OPEN ACCESS

Articles

Page Path
HOME > Cancer Res Treat > Volume 35(1); 2003 > Article
Original Article
Clinical Experience in Conformal Stereotactic Radiotherapy of Irregularly Shaped Intracranial Tumors
Ki Hwan Kim, Moon June Cho, Dong Wuk Kim, Jun Sang Kim, Seon Hwan Kim, Chang Joon Song, Shi Hun Song, Ji Young Jang, Jae Sung Kim
Cancer Research and Treatment 2003;35(1): 69-74.
DOI: https://doi.org/10.4143/crt.2003.35.1.69
Published online: February 28, 2003
1Department of Therapeutic Radiology, Chungnam NationalUniversity, Chungnam, Korea. mjcho@cun.ac.kr
2Department of Neurosurgery, Chungnam National University,Chungnam, Korea.
3Department of Diagnostic Radiology, College of Medicine,Chungnam National University, Chungnam, Korea.
4Cancer Research Institute, Chungnam National University,Chungnam, Korea.
  • 4,442 Views
  • 21 Download
  • 1 Crossref
  • 0 Scopus
prev next

PURPOSE
The dosimetric advantages of multiple non-coplanar stationary fields for stereotactic radiotherapy or adiosurgery (SRT/S) are well known. However, this technique is not widely used due to the logistical problems associated with producing and testing customized collimators. We report our experience of SRT/S using multiple non-coplanar stationary fields (conformal SRT/ S). MATERIALS AND METHODS: Between August 1997 and February 2002, we performed frameless SRT/S in 63 patients. We chose conformal SRT/S when the tumor was of a very irregular shape or larger than 4 cm. We obtained three pieces of information: 1) the couch translations required to bring the target point to the isocenter, 2) the distance between the stereotaxic markers in the CT study, and the distance between the markers determined from orthogonal beam films, taken in the anterior- posterior and lateral directions, and 3) the rotational movement of the head position between the CT study and actual treatment position. We evaluated two kinds of data: 1) the precision of the isocenter setup, and 2) the reproducibility of the head position in the a) translational and b) rotational components. RESULTS: Twenty-six of the 63 patients receiving stereotactic treatment received conformal SRT/S. The precision of the isocenter setup for the conformal SRT/S was x=-0.03+/-0.26 mm, y=0.19+/-0.25 mm and z=-0.20+/-0.27 mm. The reproducibilities of the head position with the conformal SRT/S were 0.5 mm and less than 1degrees C, for the translational and rotational components, in any plane. CONCLUSION: We were able to apply conformal stereotactic irradiation, which has a dosimetric advantage, to irregularly shaped intracranial tumors, with precision and reproducibility of head position for the isocenter setup nearly equivalent to that of frame-based SRS or multiple-arc SRT/S.

  • Cite
    CITE
    export Copy Download
    Close
    Download Citation
    Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

    Format:
    • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
    • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
    Include:
    • Citation for the content below
    Clinical Experience in Conformal Stereotactic Radiotherapy of Irregularly Shaped Intracranial Tumors
    Cancer Res Treat. 2003;35(1):69-74.   Published online February 28, 2003
    Close

Cancer Res Treat : Cancer Research and Treatment
Close layer
TOP